Analytical Chemistry · 2019 · 53 citations · 52 references
Natural SciencesChemistryNeuroscienceAnalytical ChemistryElectroanalytical MethodsElectrochemistryElectroanalytical ChemistryElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsBackground SubtractionElectrochemical BioanalysisElectrochemical SensingPartial Least Squares RegressionVoltammetric BiosensorsVoltammetric DetectionVoltammetric SensingVoltammetry
Background-subtracted fast-scan cyclic voltammetry (FSCV) provides a method for detecting molecular fluctuations with high spatiotemporal resolution in the brain of awake and behaving animals. The rapid scan rates generate large background currents that are subtracted to reveal changes in analyte concentration. Although these background currents are relatively stable, small changes do occur over time. These changes, referred to as electrochemical drift, result in background-subtraction artifacts that constrain the utility of FSCV, particularly when quantifying chemical changes that gradually occur over long measurement times (minutes). The voltammetric features of electrochemical drift are varied and can span the entire potential window, potentially obscuring the signal from any targeted analyte. We present a straightforward method for extending the duration of a single FSCV recording window. First, we have implemented voltammetric waveforms in pairs that consist of a smaller triangular sweep followed by a conventional voltammetric scan. The initial, abbreviated waveform is used to capture drift information that can serve as a predictor for the contribution of electrochemical drift to the subsequent full voltammetric scan using partial-least-squares regression (PLSR). This double-waveform partial-least-squares regression (DW-PLSR) paradigm permits reliable subtraction of the drift component to the voltammetric data. Here, DW-PLSR is used to improve quantification of adenosine, dopamine, and hydrogen peroxide fluctuations occurring >10 min from the initial background position, both in vitro and in vivo. The results demonstrate that DW-PLSR is a powerful tool for evaluating and interpreting both rapid (seconds) and gradual (minutes) chemical changes captured in FSCV recordings over extended durations.
52
Partial least-squares regression: a tutorial
Paul Geladi, Bruce R. Kowalski · Analytica Chimica Acta · 1986 · 6.9K citations
The mouse brain in stereotaxic coordinates
Jan Pieter Konsman · Psychoneuroendocrinology · 2003 · 4.1K citations
Medicine, Neurobiology, Neuroscience +12
Subsecond dopamine release promotes cocaine seeking
Paul E. M. Phillips, Garret D. Stuber, Michael L. Heien et al. · Nature · 2003 · 1.1K citations
Dopamine Operates as a Subsecond Modulator of Food Seeking
Mitchell F. Roitman, Garret D. Stuber, Paul E. M. Phillips et al. · Journal of Neuroscience · 2004 · 717 citations · Full text
Prefrontal Acetylcholine Release Controls Cue Detection on Multiple Timescales
Vinay Parikh, Rouba Kozak, Vicente Martínez et al. · Neuron · 2007 · 656 citations · Full text