Energy Procedia · 2019 · 31 citations · 34 references
EngineeringElectrical EngineeringPower ElectronicsRenewable Energy IntegrationRenewable Energy SystemsDc-ac InvertersDistributed Energy ResourcesRenewable Energy Power ConversionSolar Energy SystemsSolar Photovoltaic SystemsVoltage RegulationGrid-connected Photovoltaic SystemsHarmonic DistortionInverter SystemsMaximum Power Point TrackingPhotovoltaic InvertersPower FactorReactive Power ControlVoltage
The aim of this paper is to present a command approach of a typical double-stage grid-connected PV system functioning under normal conditions and Symmetrical Grid Voltage Dips (SGVD). In Normal Operation Mode (NOM), the command developed rises the relatively low solar voltage to a suitable level corresponds to the Maximal Power Point Tracking (MPPT) and regulates, respectively, the dc-link voltage and the output inverter currents. It permits to inject energy into the grid at unity power factor and a current with low harmonic distortion. Under SGVD, the control strategy approach should ensure a stable connection as long as possible and inject some reactive power to support the grid faults. This command calculates dynamically active and reactive powers that inverter can deliver according to the level of voltage dips and inverter rating currents. Those values are used as reference to control output inverter currents, the dc-link voltage and to deactivate the MPPT command. To validate and to prove the effectiveness of the control strategy, some experimental results are also presented.
34
Young-Sang Bae, Trung-Kien Vu, Rae-Young Kim · IEEE Transactions on Energy Conversion · 2013 · 256 citations