Radiotherapy and Oncology · 2019 · 19 citations · 13 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation ProtectionTreatment PlanningCancer Treatment PlanningRadiation TherapyRadiation Treatment PlanningStereotactic RadiotherapyTarget Volume DelineationTreatment Planning Dose CalculationClinical Target Volume CoverageInternal Target Volume ReductionRadiotherapy Plan EvaluationStereotactic Ablative RadiotherapyStereotactic Radiotherapy PlanningSystematic UncertaintiesTarget Coverage EvaluationTreatment Planning Margins
BACKGROUND AND PURPOSE: Stereotactic ablative body radiotherapy for lung plans requires 4DCT. Most radiotherapy centres use this to determine an internal target volume (ITV), despite studies suggesting that planning on a mid-ventilation (Mid-V) phase can reduce target volumes. The purpose of this study is two-fold: to determine whether the Mid-V approach provides adequate coverage and to discuss methods to enable the Mid-V approach to be applied more widely. METHOD: 4D scans of 79 patients were outlined on every phase. The mid-V phase was identified. Margins were determined from the range of motion, and plans generated with a 55 Gy prescription. A grid-based method was used to get the probability of tumour coverage in the presence of systematic and random uncertainties, with and without blurring for breathing motion. RESULTS: For the Mid-V plans with the margins calculated from the van-Herk formula, after blurring doses for breathing, the coverage (dose covering 95% of the CTV 95% of the time) was greater than for plans with isotropic 5 mm margins uncorrected for breathing (58.2 Gy v 57.3 Gy). Similar results were obtained for a linear margin chosen as 0.15 of the breathing range. Deformable contour propagation in a commercial outlining system (ProSoma) identified the same mid-V phase in the majority of cases. CONCLUSION: Our results confirm that a mid-V approach can be used to reduce the PTV size, with no loss of tumour coverage. We propose the use of a simplified margin formula equal to the margin ignoring breathing plus 0.15 of the range of motion.
13
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Paul Keall, G Mageras, James M. Balter et al. · Medical Physics · 2006 · 2.3K citations · Full text
J. Wolthaus, Jan‐Jakob Sonke, Marcel van Herk et al. · International Journal of Radiation Oncology*Biology*Physics · 2008 · 297 citations · Full text
J. Wolthaus, Christoph Schneider, Jan‐Jakob Sonke et al. · International Journal of Radiation Oncology*Biology*Physics · 2006 · 271 citations