OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1989 · 10 citations · 0 references
EngineeringChemical EngineeringEnvironmental EngineeringCombustionHazardous Waste ManagementWaste ManagementSoil PollutionWaste CharacterizationWaste DisposalWaste GenerationWaste IncinerationWaste ReductionIncineration FacilitiesMixed Waste TreatmentOxygen-enriched CombustionParticulate EmissionsParticulate Matter EmissionsRemoval EfficiencyRotary Kiln IncinerationSuperfund Sites
A series of demonstration tests of the American Combustion, Inc., Thermal Destruction System was performed under the SITE program. This oxygen-enhanced combustion system was retrofit to the rotary-kiln incinerator at EPA's Combustion Research Facility. The system's performance was tested firing contaminated soil from the Stringfellow Superfund Site, both alone and mixed with a coal tar waste (KO87). Comparative performance with conventional incinerator operation was also tested. Compliance with the incinerator performance standards of 99.99% principal organic hazardous constituents (POHC) destruction and removal efficiency and particulate emissions of less than 180 mg/dscm at 7% O2 was measured for all tests. The Pyretron system was capable of in-compliance performance at double the mixed waste feedrate and at a 60% increase in batch waste charge mass than possible with conventional incineration. Scrubber blowdown and kiln ash contained no detectable levels of any of the POHCs chosen.