Diabetes Technology & Therapeutics · 2019 · 52 citations · 20 references
MedicineEndocrinologyPediatricsAdolescent HealthDiabetologyPediatric EndocrinologyBlood Glucose MonitoringDiabetes ManagementDiabetes MellitusDiabetes Self-managementGlycemic ControlGlycemic MonitoringBlood Glucose RegulationDiabetes Management In ChildrenGlucose MonitoringGlucose Monitoring FrequencyPediatric Diabetes Self-managementPediatric Glucose MonitoringSevere Hypoglycemia ManagementType 1 Diabetes Monitoring
Background: Flash glucose monitoring (FGM) is covered by the Belgian public health insurance for type 1 diabetes since 2016. The objective of this study was to describe the use of FGM and diabetes outcomes in type 1 diabetic children and adolescents 1 year after reimbursement. Methods: All patients had the choice to convert to FGM or to continue with self-monitoring of blood glucose (SMBG). Clinical data were collected at baseline, at the next visit, and after 12 months; glucose profiles at next visit and after 12 months. Regression analyses were performed to identify predictors of FGM acceptance and changes in metabolic control. Results: A total of 334 subjects were included, of whom 278 (83.2%) switched to FGM. They were younger (13.6 vs. 15.2 years; P = 0.012) and performed more SMBG testing at baseline than patients who did not switch (4.3 vs. 4.1 tests daily; P = 0.008). At the end of follow-up, the rate of severe hypoglycemia decreased by 53% in the group of FGM users ( P = 0.012) while it remained stable in SMBG users. Median glycated hemoglobin did not change significantly in both groups. Among subjects who switched to FGM, 15.8% reverted to SMBG after a median use of 5.3 months. Adverse events, diabetes duration, and FGM utilization were independent predictors of the risk for reverting. FGM-related adverse events were associated with a fivefold increased risk to revert to SMBG (hazard ratio = 5.12; P < 0.0001). Conclusions: FGM is relatively well accepted and decreases the risk of severe hypoglycemic events in our pediatric population. FGM is more often discontinued in patients experiencing adverse events and with longer diabetes duration.
20
Cross sectional stature and weight reference curves for the UK, 1990.
Jenny Freeman, Tim Cole, S Chinn et al. · Archives of Disease in Childhood · 1995 · 1.5K citations · Full text
Type 1 Diabetes Through the Life Span: A Position Statement of the American Diabetes Association
Jane L. Chiang, M. Sue Kirkman, Lori M. Laffel et al. · Diabetes Care · 2014 · 969 citations · Full text
Medicine, Endocrinology, Immunology +15
Andrew J. Karter, Lynn Ackerson, Jeanne Darbinian et al. · The American Journal of Medicine · 2001 · 598 citations
Medicine, Chronic Disease Control, Chronic Disease Prevention +14