Journal of Mass Spectrometry · 2019 · 12 citations · 39 references
Natural SciencesChemistryPharmacologyAnalytical ChemistryMass Spectrometric AnalysisMolecular ImagingInstrumental AnalysisIonization TechniquesMass Spectrometric ImagingMass SpectrometryMass Spectrometric Drug AnalysisMatrix-assisted Laser Desorption ImagingMatrix-assisted Laser Desorption/ionizationMatrix-assisted Laser Desorption/ionization ImagingMatrix-assisted Laser Desorption/ionization Time-of-flight Mass SpectrometryMatrix-assisted Laser Ionization ImagingSample PretreatmentSputtering
Sample pretreatment is key to obtaining good data in matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Although sublimation is one of the best methods for obtaining homogenously fine organic matrix crystals, its sensitivity can be low due to the lack of a solvent extraction effect. We investigated the effect of incorporating a thin film of metal formed by zirconium (Zr) sputtering into the sublimation process for MALDI matrix deposition for improving the detection sensitivity in mouse liver tissue sections treated with olanzapine. The matrix-enhanced surface-assisted laser desorption/ionization (ME-SALDI) method, where a matrix was formed by sputtering Zr to form a thin nanoparticle layer before depositing MALDI organic matrix comprising α-cyano-4-hydroxycinnamic acid (CHCA) by sublimation, resulted in a significant improvement in sensitivity, with the ion intensity of olanzapine being about 1800 times that observed using the MALDI method, comprising CHCA sublimation alone. When Zr sputtering was performed after CHCA deposition, however, no such enhancement in sensitivity was observed. The enhanced sensitivity due to Zr sputtering was also observed when the CHCA solution was applied by spraying, being about twice as high as that observed by CHCA spraying alone. In addition, the detection sensitivity of these various pretreatment methods was similar for endogenous glutathione. Given that sample preparation using the ME-SALDI-MSI method, which combines Zr sputtering with the sublimation method for depositing an organic matrix, does not involve a solvent, delocalization problems such as migration of analytes observed after matrix spraying and washing with aqueous solutions as sample pretreatment are not expected. Therefore, ME-Zr-SALDI-MSI is a novel sample pretreatment method that can improve the sensitivity of analytes while maintaining high spatial resolution in MALDI-MSI.
39
Ion formation in MALDI mass spectrometry
Renato Zenobi, Richard Knochenmuss · Mass Spectrometry Reviews · 1998 · 778 citations
Clathrate nanostructures for mass spectrometry
Trent R. Northen, Óscar Yanes, Michael T. Northen et al. · Nature · 2007 · 471 citations