International Journal of Advanced Structural Engineering · 2019 · 37 citations · 18 references
EngineeringMaterials EngineeringMaterials ScienceStructural AnalysisStructural EngineeringStructural MaterialsBuckling Of ColumnsConcrete ConstructionDuctilityFlexural PropertiesReinforced Concrete StructuresStructural ReinforcementBucklingColumn StrengtheningColumnsCompressive StrengthFlexural StrengthReinforced ConcreteReinforced Concrete StrengtheningStructural Strengthening
FRP wrapping and NSM reinforcement are effective methods for enhancing the shear capacity, ductility, and flexural strength of reinforced concrete columns while preventing buckling. The study investigates the strengthening of RC columns by combining NSM rebars with an FRP jacket using finite element modeling. Validated numerical models were used to conduct a parametric study varying axial load, FRP confinement location, jacket ply count, jacket fiber type, NSM reinforcement ratio, and concrete strength to assess their impact on strengthened column behavior. The optimum jacket ply count for desired ductility is achieved when the maximum confined concrete strain is 0.008, and increasing the NSM reinforcement ratio from 0.16 % to 1 % raises lateral strength by about 28 % while reducing the ductility factor by roughly 50 %.
Fiber-reinforced polymer (FRP) wrapping of reinforced concrete (RC) columns is an effective way to improve their shear capacity and ductility and prevent buckling in their longitudinal reinforcements. Another strengthening method called the near surface mounted (NSM) reinforcement has been proven effective in improving the flexural strength of RC columns. In this research, the strengthening of RC columns with the combined use of NSM rebars and FRP jacket was studied using a finite element modeling approach. After validating the numerical models with the existing experimental data, a comprehensive parametric study was performed to determine the effect of axial load, implementing the FRP confinement around the base or over the entire height of the column, the number of plies of FRP jacket, the type of jacket fiber, the ratio of NSM reinforcement, and the compressive strength of the concrete on the behavior of the strengthened RC columns. The results show that the optimum number of plies of jacket for reaching a desirable level of ductility can be determined by setting the maximum compressive strain in the confined concrete, $$\varepsilon_{\text{ccu}}$$ , to 0.008. Increasing the ratio of NSM reinforcement from 0.16% of the total cross-sectional area to 1% led to approximately 28% increase in the lateral strength and 50% decrease in the ductility factor.
18
Failure Criteria for Unidirectional Fiber Composites
Zvi Hashin · Journal of Applied Mechanics · 1980 · 4.5K citations