The Journal of Urology · 2019 · 10 citations · 0 references
Natural SciencesSurgeryUrologyBiomedical OpticsBiophotonicsUrolithiasisBiomedical Laser ApplicationsFiber OpticsLaser PhysicsLaser-tissue InteractionOptical FibersFibers
You have accessJournal of UrologyStone Disease: Basic Research & Pathophysiology I (MP03)1 Apr 2019MP03-20 DUSTING EFFICIENCY COMPARISON BETWEEN MOSES TECHNOLOGY OF HO:YAG LASER AND SUPERPULSE THULIUM FIBER LASER Vincent De Coninck*, Etienne Xavier Keller, Anastasiya Kovalenko, Viktoriya Vinnichenko, and Olivier Traxer Vincent De Coninck*Vincent De Coninck* More articles by this author , Etienne Xavier KellerEtienne Xavier Keller More articles by this author , Anastasiya KovalenkoAnastasiya Kovalenko More articles by this author , Viktoriya VinnichenkoViktoriya Vinnichenko More articles by this author , and Olivier TraxerOlivier Traxer More articles by this author View All Author Informationhttps://doi.org/10.1097/01.JU.0000554952.38129.59AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVES: At present, the Ho:YAG laser is the most commonly used laser for treating urolithiasis. A new technology of the Ho:YAG laser (Moses technology) was designed to increase ablation efficiency and to reduce stone retropulsion. Recently, a thulium fiber laser (TFL) has been suggested as an alternative laser source, with a potential for higher ablative efficiency and lower retropulsion. The aim of this study was to compare the efficiency of stone dusting between a Ho:YAG laser with Moses technology and a SuperPulse TFL. METHODS: A SuperPulse TFL generator was compared to a Ho:YAG laser generator with Moses technology. 200 µm fibers were used in all experiments. Laser lithotripsy was performed with a flexible ureteroscope (Pusen) for direct vision and fiber control. Uric acid stones were used in this study. Irrigation pressure was 40 cm H2O. Lithotripsy was performed in a specially constructed vessel of 13 mm in diameter, with 2 mm holes drilled in the walls at a height of 40 mm to allow collection of stone dust from irrigation overflow (Figure 1). The laser parameters for both systems were 0.2 J and 80 Hz (16 W). Lithotripsy was performed during 2′30″. After lithotripsy, the solution from the outer cuvette was filtered through filter paper with a pore size of 2 µm allowing stone dust collection. The weight of stone dust was calculated as the difference between weight of the dried filter with the stone dust and the initial weight of the filter. Experiments were repeated 5 times. RESULTS: Initial stone mass was 210±24 mg. The weight of stone dust after lithotripsy was 69±32 mg for Ho:YAG laser lithotripsy with Moses technology and 138±25 mg for the SuperPulse TFL (Figure 2). CONCLUSIONS: The SuperPulse TFL produced twice as much stone dust as the Ho:YAG laser with Moses technology. When these promising results are confirmed in future studies, the SuperPulse TFL may be able to significantly reduce operating times. Source of Funding: none Brasschaat, Belgium; Paris, France; Moscow, Russian Federation; Paris, France© 2019 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 201Issue Supplement 4April 2019Page: e28-e29 Advertisement Copyright & Permissions© 2019 by American Urological Association Education and Research, Inc.MetricsAuthor Information Vincent De Coninck* More articles by this author Etienne Xavier Keller More articles by this author Anastasiya Kovalenko More articles by this author Viktoriya Vinnichenko More articles by this author Olivier Traxer More articles by this author Expand All Advertisement PDF downloadLoading ...