Physics in Medicine and Biology · 2019 · 10 citations · 18 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAttenuation CorrectionBody ImagingComputed TomographyMedical ImagingPositron Emission TomographyComputed Tomography-based Attenuation CorrectionMotion Correction In PetPet Attenuation CorrectionPet Image ReconstructionPet QuantificationRespiratory Motion CompensationRespiratory Motion CorrectionStatic Pet Imaging
Abstract Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to static-whole-body (SWB) PET. However, to achieve this improvement, QPG PET requires CT attenuation correction data that matches the QPG PET data. In this paper we investigated the effect of using free-breathing CT for attenuation correction of QPG PET on SUV max and SUV peak and compared the results to those of SWB PET. 34 lesions in 27 patients were included. All patients were injected with F-18 FDG. 4D-CT datasets representing all possible phases of respiration that could result from a free-breathing CT were acquired. The 4D-CT datasets were used for attenuation correction of the QPG and SWB PET data. Percentage change in the SUV max and SUV peak range was calculated for the reconstructions and compared between QPG and SWB PET. The mean percentage change in the lesion SUV max and SUV peak ranges were 19.1% ( p = 0.0178) and 25.2% ( p = 0.0002) higher for QPG compared to SWB, respectively. The maximum percent change in SUV max and SUV peak ranges were 58.5% and 59.0% for QPG, respectively compared to 46.1% and 45.3% for SWB, respectively. The highest SUV max and SUV peak measurements corresponded to the CT phase that matched the QPG phase. Utilizing free-breathing CT for attenuation correction can lead to large changes in quantification due to misalignment with PET data. This misalignment has a large quantitative impact on QPG PET as compared to SWB PET. When interpreting quantitative changes in lesions, it is critical to consider the influences of free-breathing CT-based attenuation correction.
18
Physical Performance of the new hybrid PET/CT Discovery-690
Valentino Bettinardi, Luca Presotto, E. Rapisarda et al. · Medical Physics · 2011 · 377 citations
The CT motion quantitation of lung lesions and its impact on PET-measured SUVs.
Yusuf E. Erdi, Sadek A. Nehmeh, Tinsu Pan et al. · PubMed · 2004 · 283 citations
Deep-inspiration breath-hold PET/CT of the thorax.
Sadek A. Nehmeh, Yusuf E. Erdi, Gustavo Souza Portes Meirelles et al. · PubMed · 2007 · 150 citations