Circulation · 1961 · 65 citations · 10 references
Electrophysiological EvaluationHeart FailureCardiovascular DiseaseCoronary UnitMyocardial InfarctionDiagnosisStandard ElectrocardiogramClinical AppraisalCardiologyGrishman Cube SystemAcute Myocardial InfarctionPublic HealthMedicineSuspected Myocardial InfarctionAtherosclerosisEmergency MedicineRadiologyCardiovascular Imaging
A total of 161 vectorcardiograms was recorded with the Grishman cube system in patients with suspected myocardial infarction. In the group of 49 cases subsequently examined post mortem and of 73 non-autopsied cases, in whom the diagnosis of infarction appeared certain, a comparison was made between the standard electrocardiogram and the vectorcardiogram taken in succession. The vectorcardiogram demonstrated more infarcts than the electrocardiogram. Of a total of 122 cases in which the vectorcardiogram showed infarction, 19 had normal and 17 equivocal electrocardiograms. A number of simple and easily applicable criteria for the vectorcardiographic diagnosis of infarction are given. It appears that even the older, uncorrected cubelead system permits a more accurate diagnosis than currently available standard electrocardiographic procedure. It is suggested that this method of exploration may be useful in cases of suspected myocardial infarction in which the routine electrocardiographic examination leaves doubt.
10
New Bases of Electrocardiography
Journal of the American Medical Association · 1956 · 318 citations · Full text
Arthur Grishman, Leonard Scherlis, Richard P. Lasser · The American Journal of Medicine · 1953 · 80 citations