European Journal of Ophthalmology · 2019 · 18 citations · 10 references
MedicineOphthalmologySurgeryOcular TraumaOphthalmic SurgeryRefractive SurgeryAnterior Segment TraumaGlaucomaTraumatic CataractVitreoretinal SurgeryAnterior Chamber DimensionsIntraocular Pressure ReductionMacular TraumaPostoperative Intraocular Pressure MeasurementPostoperative Visual AcuityPupillary TraumaTraumatic Cataract SurgeryTraumatic Eye Injury Repair
AIM: The aim of this study is to evaluate the efficacy of pupil cerclage and a new variant of sliding knot technique for repairing traumatic mydriasis. DESIGN: This is a observational case series study. SETTING/METHODS: A series of consecutive patients affected by traumatic permanent mydriasis who underwent pupil cerclage were recruited at the Department of Ophthalmology of the University of Padova, Italy. Best-corrected visual acuity, measured in logarithm of minimum angle of resolution (logMAR), and intraocular pressure at 1, 3, 6, and 12 months were monitored. Postoperative pupil size and anterior chamber angle were measured. Postoperative cystoid macular edema (CME) and glaucoma were evaluated. RESULTS: Twelve patients were recruited. Phakic patients (7) underwent cataract surgery combined with pupil cerclage. Vitrectomy was performed in nine patients. Best-corrected visual acuity improved from 2.9 ± 1.1 logMAR at baseline to 0.3 ± 0.8 logMAR at 12th month. No significant difference between the preoperative and postoperative intraocular pressure was demonstrated. Mean pupil size at 12th month was 2.82 ± 0.5 mm with round shape. Anterior chamber angle mean was 47° ± 4.5°. Six patients developed a CME, and two patients a glaucoma. CONCLUSION: Pupil cerclage technique reestablishes the pupil with a precise regulation of the pupil size without distortion of its natural round shape. New sliding knot allows surgeon to reduce the risk of iatrogenic iris damage and to make a security permanent knot.
10
Changes of Higher Order Aberration With Various Pupil Sizes in the Myopic Eye
Yan Wang, Kanxing Zhao, Ying Jin et al. · Journal of Refractive Surgery · 2003 · 179 citations
The closed chamber slipping suture technique for iris repair.
S B Siepser · PubMed · 1994 · 137 citations
Medicine, Ophthalmology, Surgery +15
Stewart MacKay Wolff, Lorenz E. Zimmerman · American Journal of Ophthalmology · 1962 · 127 citations
Mechanical performance of surgical sutures
John G. Thacker, George T. Rodeheaver, James W. Moore et al. · The American Journal of Surgery · 1975 · 91 citations
Single-Pass Four-Throw Technique for Pupilloplasty
Priya Narang, Amar Agarwal · European Journal of Ophthalmology · 2016 · 70 citations
Medicine, Ophthalmology, Surgery +6