American Journal of Neuroradiology · 2019 · 48 citations · 32 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingMagnetic Resonance ImagingMedical ImagingNeuro-oncologic ImagingNeuro-oncology ImagingContrast-enhanced Imaging Dose OptimizationGradient Echo SequencesLeakageMagnetic Resonance Imaging Protocol OptimizationReference Standard ComparisonReference Standard ConstructionSignal-to-noise RatioVariable Flip Angle Sequences
<h3>BACKGROUND AND PURPOSE:</h3> DSC-MR imaging using preload, intermediate (60°) flip angle and postprocessing leakage correction has gained traction as a standard methodology. Simulations suggest that DSC-MR imaging with flip angle = 30° and no preload yields relative CBV practically equivalent to the reference standard. This study tested this hypothesis in vivo. <h3>MATERIALS AND METHODS:</h3> Eighty-four patients with brain lesions were enrolled in this 3-institution study. Forty-three patients satisfied the inclusion criteria. DSC-MR imaging (3T, single-dose gadobutrol, gradient recalled-echo–EPI, TE = 20–35 ms, TR = 1.2–1.63 seconds) was performed twice for each patient, with flip angle = 30°–35° and no preload (P−), which provided preload (P+) for the subsequent intermediate flip angle = 60°. Normalized relative CBV and standardized relative CBV maps were generated, including postprocessing with contrast agent leakage correction (C+) and without (C−) contrast agent leakage correction. Contrast-enhancing lesion volume, mean relative CBV, and contrast-to-noise ratio obtained with 30°/P−/C−, 30°/P−/C+, and 60°/P+/C− were compared with 60°/P+/C+ using the Lin concordance correlation coefficient and Bland-Altman analysis. Equivalence between the 30°/P−/C+ and 60°/P+/C+ protocols and the temporal SNR for the 30°/P− and 60°/P+ DSC-MR imaging data was also determined. <h3>RESULTS:</h3> Compared with 60°/P+/C+, 30°/P−/C+ had closest mean standardized relative CBV (<i>P</i> = .61), highest Lin concordance correlation coefficient (0.96), and lowest Bland-Altman bias (μ = 1.89), compared with 30°/P−/C− (<i>P</i> = .02, Lin concordance correlation coefficient = 0.59, μ = 14.6) and 60°/P+/C− (<i>P</i> = .03, Lin concordance correlation coefficient = 0.88, μ = −10.1) with no statistical difference in contrast-to-noise ratios across protocols. The normalized relative CBV and standardized relative CBV were statistically equivalent at the 10% level using either the 30°/P−/C+ or 60°/P+/C+ protocols. Temporal SNR was not significantly different for 30°/P− and 60°/P+ (<i>P</i> = .06). <h3>CONCLUSIONS:</h3> Tumor relative CBV derived from low–flip angle, no-preload DSC-MR imaging with leakage correction is an attractive single-dose alternative to the higher dose reference standard.
32
Practical Statistics for Medical Research.
Sophie Walter, Daniel Altman · Biometrics · 1992 · 11.7K citations
Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging
Robert J. McDonald, Jennifer S. McDonald, David F. Kallmes et al. · Radiology · 2015 · 1.3K citations
Medicine, Neuroscience, Radiology +14
Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.
Hannu J. Aronen, I. E. Gazit, David N. Louis et al. · Radiology · 1994 · 908 citations
Jerrold L. Boxerman, Kathleen M. Schmainda, Robert M. Weisskoff · PubMed · 2006 · 648 citations · Full text