American Journal of Neuroradiology · 2019 · 24 citations · 24 references
MedicineNeurologyRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingMultiple SclerosisNeurologic ImagingDemyelinating PlaquesInterrater AgreementMagnetic Resonance Imaging InterpretationMagnetization Transfer ImagingMagnetization Transfer SequencesPositive Predictive ValueSpin Echo ImagingSusceptibility-weighted Imaging
BACKGROUND AND PURPOSE: Gadolinium SWI is MR imaging that has recently been reported to be effective in the evaluation of several neurologic disorders, including demyelinating diseases. Our aim was to analyze the accuracy of gadolinium SWI for detecting the imaging evidence of active inflammation on MS plaques when a BBB dysfunction is demonstrated by a focal gadolinium-enhanced lesion and to compare this technique with gadolinium-enhanced T1 spin-echo and T1 spin-echo with magnetization transfer contrast. MATERIALS AND METHODS: MR imaging studies of 103 patients (170 examinations) were performed using a 1.5T scanner. Two neuroradiologists scrutinized signal abnormalities of the demyelinating plaques on gadolinium SWI and compared them with gadolinium T1 before and after an additional magnetization transfer pulse. Interrater agreement was evaluated among gadolinium T1 magnetization transfer contrast, gadolinium SWI, and gadolinium T1 spin-echo using the κ coefficient. The T1 magnetization transfer contrast sequence was adopted as the criterion standard in this cohort. Thus, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated for gadolinium T1 spin-echo and gadolinium SWI sequences. RESULTS: Differences in BBB dysfunction were evident among gadolinium SWI, gadolinium T1 spin-echo, and gadolinium T1 magnetization transfer contrast. Gadolinium T1 magnetization transfer contrast demonstrated the highest number of active demyelinating plaques. Gadolinium SWI was highly correlated with gadolinium T1 magnetization transfer contrast in depicting acute demyelinating plaques (κ coefficient = 0.860; sensitivity = 0.837), and these techniques provided better performance compared with gadolinium T1 spin-echo (κ coefficient = 0.78; sensitivity = 0.645). CONCLUSIONS: Gadolinium SWI was able to better detect BBB dysfunction in MS plaques and had a better performance than gadolinium T1 spin-echo. Increasing SWI sequence applications in clinical practice can improve our knowledge of MS, likely allowing the addition of BBB dysfunction analysis to the striking findings of the previously reported central vein sign.
24
Magnetic susceptibility-weighted MR phase imaging of the human brain.
Alexander Rauscher, Jan Sedlacik, Markus Barth et al. · PubMed · 2005 · 227 citations · Full text
Medicine, Neuroscience, Radiology +17
Ultra-high-field imaging distinguishes MS lesions from asymptomatic white matter lesions
Emma Tallantyre, Jennifer Dixon, Ian Donaldson et al. · Neurology · 2011 · 217 citations · Full text
Dragan Stojanov, Aleksandra Aracki-Trenkić, Slobodan Vojinović et al. · European Radiology · 2015 · 209 citations