2019 · 20 citations · 3 references
EngineeringElectrical EngineeringAnalog ElectronicsBiomedical ImagingDiagnostic ImagingAnalog Integrated CircuitsDifferential AmplifiersDigital Integrated CircuitsDigital Signal ProcessingLow-power Digital Circuit DesignMixed-signal Integrated Circuit DesignAnalog Amplifier DesignAnalog-digital ConversionAnalog-to-digital ConversionAnalog-to-digital Converter DesignAnalog-to-digital ConvertersDigital-to-analog ConvertersInput Impedance MatchingRamp Design
The two-step SAR architecture has been a popular choice for power-efficient ADCs used in applications such as medical imaging. The simple and scalable architecture of the SAR ADC enables efficient multi-bit conversion per stage [1, 2] however, the maximum performance of the two-step SAR is limited by the residue amplifier. The ring amplifier (RAMP) has enabled efficient two-step SAR ADCs [3]. Despite this, RAMP-based high-precision ADCs (>16b) remain unexplored. This paper presents a two-step SAR ADC utilizing a fully differential RAMP achieving 95dB DR. Two techniques that contribute to the energy-efficiency of the ADC are also presented: dynamic digital supply and DAC impedance-matching.
3