Detection of alpha particle emitters originating from nuclear fuel inside reactor building of Fukushima Daiichi Nuclear Power Plant

Yuki Morishita, Tatsuo Torii, Hiroshi Usami, Hiroyuki Kikuchi, Wataru Utsugi, Shiro Takahira

Scientific Reports · 2019 · 36 citations · 39 references

DOIFull text

Open access

Concepts

TL;DR

An alpha‑particle imaging detector comprising a 0.05‑mm Ce:GAGG scintillator and SiPM arrays was used to wipe and analyze reactor‑building floor smear papers and a Pu sample for comparison. The measured alpha spectra (5–6 MeV) matched 238Pu, showed a strong linear correlation between smear papers and the Pu sample, revealed a 241Am peak, and indicated surface contamination exceeding 4 Bq cm⁻².

Abstract

We measured alpha emitters obtained from a reactor building in the Fukushima Daiichi Nuclear Power Plant (FDNPP) by using an alpha particle imaging detector. For developing the detector, we used a very thin (0.05-mm-thick) a cerium-doped Gd3(Ga,Al)5O12 (Ce:GAGG) scintillator and silicon photomultiplier (SiPM) arrays as the photodetector. The floor of the reactor building in FDNPP was wiped off by using smear papers, and the radioactivity of these papers was measured by the alpha particle imaging detector. In addition, we measured a Plutonium (Pu) sample (mainly 5.5 MeV alpha particles from 238Pu) obtained from a nuclear fuel facility by using of the same detector for comparison with the smear papers. The alpha spectrum was in the energy range of 5-6 MeV, which corresponds to the alpha particle energy of 238Pu (5.5 MeV). The correlation coefficient of the alpha spectra of the smear papers and the Pu sample had a strong positive linear relation. Moreover, the peak of 241Am was identified by gamma spectrum measurement. Based on these results, we report actual findings of alpha emitters in the FDNPP reactor buildings originating from nuclear fuels. The surface contamination level of alpha emitters exceeded 4 Bq/cm2.

References

39