Clinical ophthalmology · 2019 · 12 citations · 23 references
Health ProfessionsOphthalmologySurgeryAnterior SegmentOcular ImagingOphthalmic SurgeryCataract AssessmentCataract EvaluationCataract ManagementCataract SurgeryCorneal AnatomyCorneal ImagingAnterior Segment TomographyCataract Incision ArchitectureCorneal Incision SurgeryCorneal Optical Coherence TomographyCorneal Thickness AssessmentDescemet Membrane DetachmentFemtosecond Laser PulsesIntraoperative Optical Coherence Tomography
Purpose: To assess the stability and reliability of femtosecond laser-assisted cataract surgery (FLACS) incisions design and dimensions using anterior segment optical coherence tomography (AS-OCT) imaging. Setting: Renato Ambrósio Ophthalmologic Study Center from Hospital Oftalmológico de Brasília, Brasília, Brazil. Design: Prospective nonrandomized controlled case series. Methods: Eyes undergoing FLACS with triplanar main temporal clear corneal incision (CCI) were evaluated at the end of the case. Eyes that required any incision hydration, surgical complications or lacked follow-up were excluded. The AS-OCT was performed after femtosecond delivery; at the end of the case; at 1 day and at 30 days after surgery. Data of pachymetry, endothelial and epithelial gaps, Descemet detachment and CCI architecture were compared. Results: Eleven eyes from 11 patients completed follow-up. Corneal thickness was statistically different between after femtosecond delivery and the end of the case ( P -value <0.05), but without difference compared to 30 days evaluation. There was an increase of Descemet detachments ( P -value <0.05) and endothelial gaps ( P -value =0.0133) at the end of the case compared to post-femtosecond delivery. As for the architecture of the CCI, significant difference was found between the parameters of entry angle and exit angle measured with AS-OCT and the programmed. Conclusion: The AS-OCT was capable of visualizing changes in the cornea at the CCI. Despite the stress caused by manipulation, results indicated good stability of incision and reproducibility of tunnel length. Synopsis: Difference of corneal thickness at the CCI between after femtosecond and after phacoemulsification measurements ( P -value <0.05), with increase of endothelial gaps ( P -value =0.0133) and Descemet detachments ( P -value <0.05). Keywords: femtosecond, incisions, cataract, pachymetry, optical coherence tomography
23
Neil J. Friedman, Georg Schuele, Dan Andersen et al. · Journal of Cataract & Refractive Surgery · 2011 · 372 citations
Medicine, Ophthalmology, Surgery +16
Surgical Outcomes and Safety of Femtosecond Laser Cataract Surgery
Timothy V. Roberts, Michael Lawless, Shveta Jindal Bali et al. · Ophthalmology · 2012 · 231 citations
Medicine, Ophthalmology, Surgery +14
Early Experience with the Femtosecond Laser for Cataract Surgery
Shveta Jindal Bali, Chris Hodge, Michael Lawless et al. · Ophthalmology · 2012 · 215 citations
Medicine, Ophthalmology, Surgery +16