IEEE Transactions on Instrumentation and Measurement · 2019 · 11 citations · 10 references
EngineeringElectrical EngineeringInstrumentationMetrologyUncertainty QuantificationCalibrationElectrical MeasurementElectrical MetrologyEquipment CalibrationMeasurement StandardsMeasurement UncertaintyAbsolute CalibrationCurrent MeasurementCurrent Measurement AccuracyCurrent Measurement UncertaintyDirect Current MetrologyPrecision MeasurementSystematic UncertaintiesTransducers
This paper describes an absolute method for calibrating commercial 1000:1 dc current transducers (DCCTs). By adding two auxiliary windings to produce 10:1 and 100:1 ratios, we use a three-step build-up method to establish the 1000:1 current ratio standard. First, we determine the 10:1 ratios of 11 DCCTs through permutation; second, we set up a two-stage composite DCCT to produce a 100:1 ratio; after switching auxiliary windings in the two-stage setup, we then derive the 1000:1 current ratio. The experimental results show that the requirements for the current source and the current meter are not stringent; their Type-B contributions to the overall uncertainties are very small. Type-A uncertainties which include factors such as the experimental environment and possible drifts of the output offsets of the DCCTs are experimentally determined. Repeated tests show that the current ratio standard has an expanded uncertainty of 0.26 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-6</sup> for the 1000:1 ratio.
10