Differentiating supraclavicular from gluteal adipose tissue based on simultaneous PDFF and T<sub>2</sub>* mapping using a 20‐echo gradient‐echo acquisition

Daniela Franz, Maximilian N. Diefenbach, Franziska Treibel, Dominik Weidlich, Jan Syväri, Stefan Ruschke, Mingming Wu, Christina Holzapfel, Theresa Drabsch, Thomas Baum,

Journal of Magnetic Resonance Imaging · 2019 · 26 citations · 37 references

DOIFull text

Open access

Concepts

Abstract

Background Adipose tissue (AT) can be classified into white and brown/beige subtypes. Chemical shift encoding‐based water–fat MRI‐techniques allowing simultaneous mapping of proton density fat fraction (PDFF) and T 2 * result in a lower PDFF and a shorter T 2 * in brown compared with white AT. However, AT T 2 * values vary widely in the literature and are primarily based on 6‐echo data. Increasing the number of echoes in a multiecho gradient‐echo acquisition is expected to increase the precision of AT T 2 * mapping. Purpose 1) To mitigate issues of current T 2 *‐measurement techniques through experimental design, and 2) to investigate gluteal and supraclavicular AT T 2 * and PDFF and their relationship using a 20‐echo gradient‐echo acquisition. Study Type Prospective. Subjects Twenty‐one healthy subjects. Field Strength/Sequence Assessment First, a ground truth signal evolution was simulated from a single‐T 2 * water–fat model. Second, a time‐interleaved 20‐echo gradient‐echo sequence with monopolar gradients of neck and abdomen/pelvis at 3 T was performed in vivo to determine supraclavicular and gluteal PDFF and T 2 *. Complex‐based water–fat separation was performed for the first 6 echoes and the full 20 echoes. AT depots were segmented. Statistical Tests Mann‐Whitney test, Wilcoxon signed‐rank test and simple linear regression analysis. Results Both PDFF and T 2 * differed significantly between supraclavicular and gluteal AT with 6 and 20 echoes (PDFF: P &lt; 0.0001 each, T 2 *: P = 0.03 / P &lt; 0.0001 for 6/20 echoes). 6‐echo T 2 * demonstrated higher standard deviations and broader ranges than 20‐echo T 2 *. Regression analyses revealed a strong relationship between PDFF and T 2 * values per AT compartment (R 2 = 0.63 supraclavicular, R 2 = 0.86 gluteal, P &lt; 0.0001 each). Data Conclusion The present findings suggest that an increase in the number of sampled echoes beyond 6 does not affect AT PDFF quantification, whereas AT T 2 * is considerably affected. Thus, a 20‐echo gradient‐echo acquisition enables a multiparametric analysis of both AT PDFF and T 2 * and may therefore improve MR‐based differentiation between white and brown fat. Level of Evidence : 2 Technical Efficacy : Stage 2 J. Magn. Reson. Imaging 2019;50:424–434.

References

37