Sampling of urine for diagnosing urinary tract infection in general practice – First-void or mid-stream urine?

Hoelmkjaer Pernille, Lars Bjerrum, Marjukka Mākelä, Volkert Siersma, Anne Holm

Scandinavian Journal of Primary Health Care · 2019 · 27 citations · 17 references

DOIFull text

Open access

Abstract

All three POC tests performed on MSU were significantly more in agreement with the reference than when performed on FVU when analysis was done immediately. The error rate was 16% for MSU vs. 23% for FVU with POC culture, 27% vs. 40% with microscopy and 25% vs. 33% with dipstick testing. Delay of analysis up to four hours did not decrease agreement with the reference. Conclusion/Implication: MSU samples should be used in general practice for optimal accuracy of POC tests. Analysis can be delayed up to four hours. Key points Point-of-care tests (dipstick testing, microscopy and culture) for diagnosing urinary tract infection performed on mid-stream urine samples are significantly more accurate than when performed on first-void urine samples. Delay of analysis up to four hours did not decrease the accuracy of any of the point-of-care tests. Point-of-care culture was more accurate than dipstick and microscopy both when performed on mid-stream urine and first-void urine The main contaminant in first-void urine samples was Enterococci spp., which contributed to the majority of false positives.

References

17