Heart Rhythm · 2019 · 225 citations · 11 references
MedicineCardiologyClinical CardiologyElectrophysiologyInterventional CardiologyAblation TherapyAtrial ElectrophysiologyAtrial FibrillationCardiac ArrhythmiasCatheter AblationComplication Reduction StrategiesAblation SafetyAtrial Flutter AblationHigh-power Short-duration AblationSurgical Ablation
BackgroundMany centers use radiofrequency (RF) energy at 25–35 W for 30–60 seconds. There is a safety concern about using higher power, especially on the posterior wall.ObjectiveThe purpose of this study was to examine complication rates for atrial fibrillation (AF) ablations performed with high-power, short-duration RF energy.MethodsWe examined the complication rates of 4 experienced centers performing AF ablations at RF powers from 45–50 W for 2–15 seconds per lesion. In total, 13,974 ablations were performed in 10,284 patients. On the posterior wall, 11,436 ablations used 45–50 W for 2–10 seconds, and 2538 ablations used power reduced to 35 W for 20 seconds. Esophageal temperature monitoring was used in 13,858 (99.2%).ResultsDemographics were age 64 ± 11 years, male 68%, left atrial size 4.4 ± 0.7 cm, paroxysmal AF 37%, persistent AF 42%, longstanding AF 20%, antiarrhythmic drugs failed 1.4 ± 0.7, hypertension 54%, diabetes 15%, previous cerebrovascular accident/transient ischemic attack 7%, and CHA2DS2-VASc score 2.1 ± 1.4. Procedural time was 116 ± 41 minutes. Complications were death in 2 (0.014%; 1 due to stroke and 1 due to atrioesophageal fistula), pericardial tamponade in 33 (0.24%; 26 tapped, 7 surgical), strokes <48 hours in 6 (0.043%), strokes 48 hours–30 days in 6 (0.043%), pulmonary vein stenosis requiring intervention in 2 (0.014%), phrenic nerve paralysis in 2 (0.014%; both resolved), steam pops 2 (0.014%) without complications, and catheter char 0 (0.00%). There was 1 atrioesophageal fistula in 11,436 ablations using power 45–50 W on the posterior wall and 3 in 2538 ablated with 35 W on the posterior wall (P = .021), although 2 of the 3 had no esophageal monitoring during a fluoroless procedure.ConclusionAF ablations can be performed at 45–50 W for short durations with very low complication rates. High-power, short-duration ablations have the potential to shorten procedural and total RF times and create more localized and durable lesions. Many centers use radiofrequency (RF) energy at 25–35 W for 30–60 seconds. There is a safety concern about using higher power, especially on the posterior wall. The purpose of this study was to examine complication rates for atrial fibrillation (AF) ablations performed with high-power, short-duration RF energy. We examined the complication rates of 4 experienced centers performing AF ablations at RF powers from 45–50 W for 2–15 seconds per lesion. In total, 13,974 ablations were performed in 10,284 patients. On the posterior wall, 11,436 ablations used 45–50 W for 2–10 seconds, and 2538 ablations used power reduced to 35 W for 20 seconds. Esophageal temperature monitoring was used in 13,858 (99.2%). Demographics were age 64 ± 11 years, male 68%, left atrial size 4.4 ± 0.7 cm, paroxysmal AF 37%, persistent AF 42%, longstanding AF 20%, antiarrhythmic drugs failed 1.4 ± 0.7, hypertension 54%, diabetes 15%, previous cerebrovascular accident/transient ischemic attack 7%, and CHA2DS2-VASc score 2.1 ± 1.4. Procedural time was 116 ± 41 minutes. Complications were death in 2 (0.014%; 1 due to stroke and 1 due to atrioesophageal fistula), pericardial tamponade in 33 (0.24%; 26 tapped, 7 surgical), strokes <48 hours in 6 (0.043%), strokes 48 hours–30 days in 6 (0.043%), pulmonary vein stenosis requiring intervention in 2 (0.014%), phrenic nerve paralysis in 2 (0.014%; both resolved), steam pops 2 (0.014%) without complications, and catheter char 0 (0.00%). There was 1 atrioesophageal fistula in 11,436 ablations using power 45–50 W on the posterior wall and 3 in 2538 ablated with 35 W on the posterior wall (P = .021), although 2 of the 3 had no esophageal monitoring during a fluoroless procedure. AF ablations can be performed at 45–50 W for short durations with very low complication rates. High-power, short-duration ablations have the potential to shorten procedural and total RF times and create more localized and durable lesions.
11
Vivek Y. Reddy, Srinivas R. Dukkipati, Petr Neužil et al. · Circulation · 2015 · 379 citations · Full text
Moloy Das, Jonathan J. Loveday, Gareth Wynn et al. · EP Europace · 2016 · 345 citations · Full text
Abhishek Bhaskaran, W. Chik, Jim Pouliopoulos et al. · EP Europace · 2016 · 140 citations · Full text