Applied Optics · 2019 · 126 citations · 25 references
EngineeringMaterials EngineeringMaterials ScienceBiosensorsPhotonicsSensorsOptical FibersOptical SensingOptical SensorsPlasmonic MaterialsPlasmonicsRefractive IndexAccuracyDetectionNear-infrared SensingOptical DetectionPlasmonic SensingSensingSurface Plasmon Resonance SensorsWavelength Sensitivity
A microchannel incorporated photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor for detection of low refractive index (RI) at near-infrared wavelength is presented in this paper. To attain a simple and practically feasible mechanism, plasmonic material gold (Au) and sensing medium are placed outside the fiber. A thin layer of TiO2 is employed as an adhesive layer to strongly attach the Au with the silica glass. In the sensing range of 1.22 to 1.37, maximum sensitivities of 51,000 nm/RIU (RI unit) and 1872  RIU−1 are obtained with resolutions of 1.96×10−6 and 9.09×10−6 RIUs using wavelength and amplitude interrogation methods, respectively. To the best of the authors’ knowledge, the obtained maximum wavelength sensitivity and resolution are the highest among reported PCF-based SPR sensors to date. The sensor also exhibits a maximum figure of merit of 566. Therefore, the proposed sensor would be an excellent candidate for a wide range of RI detection with higher accuracy for applications such as pharmaceutical inspection and leakage monitoring, bio-sensing, and other low RI analytes.
25
Mid-infrared surface plasmon resonance sensor based on photonic crystal fibers
Chao Liu, Lin Yang, Xili Lu et al. · Optics Express · 2017 · 294 citations · Full text