MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic Nuclear MedicineDiagnostic RadiologyComputed TomographyComputed Tomography Dose ManagementPatient-specific DosimetryPositron Emission Tomography18F-fluorodeoxyglucose ImagingComputed Tomography Dose IndicesComputed Tomography Dose MeasurementDose-length ProductFluorine-18 Fluorodeoxyglucose Positron Emission TomographyHybrid Positron Emission TomographyMedian Effective DosePet-computed Tomography
Abstract Introduction The aim of this work is to report diagnostic reference levels ( DRL s) for hybrid positron emission tomography and x‐ray computed tomography ( PET / CT ) exams in Australia ( AU ) for Queensland ( QLD ) and Western Australia ( WA ) ( AU QLD / WA ) and New Zealand ( NZ ). Methods Two‐structured booklets were designed to collect dose information, patient demographics, equipment details and acquisition protocols for fluoride‐18 fluorodeoxyglucose ( 18 F‐ FDG ) P ET / CT procedures, and any additional diagnostic CT routinely performed as part of 18 F‐ FDG whole‐body examination. The DRL was reported based on the 75 th percentile and achievable dose for 18 F‐ FDG , CT dose index volume ( CTDI vol ) and dose length product ( DLP ). The effective dose and total effective dose was reported for 18 F‐ FDG whole‐body PET / CT examination. Also, the effective dose was reported separately for identified additional diagnostic CT . Results The findings of this study show that the current DRL for 18 F‐ FDG in AU QLD/WA and NZ was 333.75 MB q and 332.87 MB q, respectively. The reported AU QLD / WA CTDI vol and DLP associated with 18 F‐ FDG whole‐body PET / CT examinations from vertex to thigh ( VT ) was 4.41 mG y and 474 mG y.cm. In NZ , the reported VT CTDI vol and DLP was 13.07 mG y and 1319.05 mG y.cm. The effective dose for 18 F‐ FDG and CT component was 5.6 mS v and 4.7 mS v for AU QLD / WA . For NZ , the effective dose was 5.7 mS v and 10.9 mS v for 18 F‐ FDG and CT component. The total effective dose delivered from the 18 F‐ FDG whole‐body scan from the AU QLD / WA PET / CT centres (10.44 mS v) were lower than the radiation doses delivered from the NZ (16.65 mS v). Conclusions The current DRL s were proposed for AU QLD / WA and NZ for 18 F‐ FDG whole‐body PET / CT examinations. Variations existed in the current practice of AU QLD/WA and NZ PET / CT examinations. There is a need to optimize the radiation doses delivered from PET / CT examinations.
16
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
E. Vañó, D.L. Miller, C J Martin et al. · Annals of the ICRP · 2017 · 981 citations