Effect of structured self‐monitoring of blood glucose, with and without additional TeleCare support, on overall glycaemic control in non‐insulin treated Type 2 diabetes: the SMBG Study, a 12‐month randomized controlled trial

Sharon Parsons, Stephen D. Luzio, Jeremy N. Harvey, Stephen C. Bain, WY Cheung, Alan Watkins, David R. Owens

Diabetic Medicine · 2019 · 42 citations · 13 references

DOIFull text

Open access

Concepts

Abstract

Abstract Aim To examine the impact of structured self‐monitoring of blood glucose, with or without TeleCare support, on glycaemic control in people with sub‐optimally controlled Type 2 diabetes. Methods We conducted a 12‐month, multicentre, randomized controlled trial in people with established (>1 year) Type 2 diabetes not on insulin therapy, with sub‐optimal glycaemic control [HbA 1c ≥58 to ≤119 mmol/mol (≥7.5% to ≤13%)]. A total of 446 participants were randomized to a control group ( n = 151) receiving usual diabetes care, a group using structured self‐monitoring of blood glucose alone ( n = 147) or a group using structured self‐monitoring of blood glucose with additional monthly ‘TeleCare’ support ( n = 148). The primary outcome was HbA 1c at 12 months. Results A total of 323 participants (72%) completed the study; 116 (77%) in the control group, 99 (67%) in the self‐monitoring of blood glucose alone group and 108 (73%) in the self‐monitoring of blood glucose plus TeleCare group. Compared to baseline, the mean HbA 1c was lower in all groups at 12 months, with reductions of 3.3 mmol/mol (95% CI –5.71 to –0.78) or 0.3% (95% CI –0.52 to –0.07; P =0.01) in the control group, 11.4 mmol/mol (95% CI –14.11 to –8.76) or 1.1% (–1.29 to –0.81; P <0.0001) in the group using self‐monitoring of blood glucose alone and 12.8 mmol/mol (95% CI –15.34 to –10.31) or 1.2% (95% CI –1.40 to ‐0.94; P <0.0001) in the group using self‐monitoring of blood glucose plus TeleCare. This represents a reduction in HbA 1c of 8.9 mmol/mol (95% CI –11.97 to –5.84) or 0.8% (95% CI –1.10 to ‐0.54; P ≤0.0001) with structured self‐monitoring of blood glucose compared to the control group. Participants with lower baseline HbA 1c , shorter duration of diabetes and higher educational achievement were more likely to achieve HbA 1c ≤53 mmol/mol (7.0%). Conclusions Structured self‐monitoring of blood glucose provides clinical and statistical improvements in glycaemic control in Type 2 diabetes. No additional benefit, over and above the use of structured self‐monitoring of blood glucose, was observed in glycaemic control with the addition of once‐monthly TeleCare support. (Clinical trial registration no.: ISRCTN21390608)

References

13