Degradation of four antibiotics from aqueous solution by ozonation: intermediates identification and reaction pathways

Mahsa Tahergorabi, Ali Esrafili, Majid Kermani, Mitra Gholami, Mahdi Farzadkia

Desalination and Water Treatment · 2019 · 18 citations · 33 references

DOIFull text

Open access

Concepts

Abstract

ABSTRACT The effects of some operational parameters like pH, initial antibiotics concentration, ozone concentration, reaction time on the degradation of four antibiotics were studied by ozonation. Under optimal conditions: pH = 5, [antibiotics] 0 = 10 mg/L and production of ozone capacity = 0.22 g/h, 100% of antibiotics were removed within 45 min. The values of electrical energy per order (E Eo ) increased from 24.7 to 47 (SCT), from 31.1 to 52 (STZ), from 32.5 to 49.7 (SMX) and from 32.5 to 51.5 (kWh m –3 ) (SDZ) with increasing antibiotics concentration from 10 to 40 mg/L, respectively. The main mechanism for the degradation of all antibiotics were governed by the formation of • OH radicals. In general, the efficacy of the processes in the removal of antibiotics from drinking water decreased due to anion scavenger activity. Intermediate products in the removal of antibiotics identified by GC/MS were organic acids. Mineralization of antibiotics by ozonation after 45 min was 34%.

References