Chemical and Pharmaceutical Bulletin · 2018 · 14 citations · 20 references
Metformin is a euglycemic drug for the treatment of type 2 diabetes mellitus. To date, there are 13 dissolution methodologies described in the U.S. Pharmacopoeia (USP) to evaluate the release profile of metformin from extended-release tablets utilizing either a USP apparatus 1 (basket) or 2 (paddle). In the absence of a protocol for a USP apparatus 3 (reciprocating cylinder), the goal of this work was to develop an in vitro dissolution method for metformin extended-release tablets based on an in vivo-in vitro correlation (IVIVC). Following a systematic evaluation, a final dissolution method, M4, was defined. It applied 30 dips per minute (dpm) over a total period of 10 h into a series of solutions that included 2 h in HCl media (pH 1.2), 1 h in an acetate buffer solution (pH 4.5), 1 h in phosphate buffer solution (PBS) (pH 5.8) and 6 h in PBS (pH 6.8). This method showed a significant IVIVC with a calculated R<sup>2</sup> > 0.98 (point-to-point correlation, Level A) and it was successfully used as a tool to assist in the development of generic extended release formulations for metformin consisting of a lipophilic matrix system.