Concepedia

Publication | Open Access

Comparison of balloon-expandable vs. self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration

138

Citations

23

References

2018

Year

Abstract

In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.

References

YearCitations

Page 1