Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting · 2017 · 13 citations · 1 references
ComputingGeophysicsGeodesyGlobal Navigation Satellite SystemsInstrumentationClock SynchronizationTime SynchronizationClock Synchronization ErrorCoordinated Universal TimeGlobal Navigation Satellite System Time SynchronizationGlobal Positioning SystemSatellite Clock ErrorSatellite Clock SynchronizationSynchronization ErrorsUniversal Time
An anomaly in GPS satellite UTC offset broadcast on January 25‑26 2016 caused many GPS‑controlled clocks to be off by about –13 µs, with 15 of the 30 satellites transmitting the error. The paper examines the technical causes of the UTC offset anomaly, its impact on GPS‑controlled clocks, and how NIST detected and assessed the effect on clocks at its Boulder and remote sites. Analysis shows the anomaly affected GPS clocks at 19 sites across North, Central, and South America, illustrating the widespread impact of the error.
Errors in the Coordinated Universal Time (UTC) offset parameters broadcast by Global Positioning System (GPS) satellites caused many thousands of GPS-controlled clocks to be in error by approximately -13 µs on January 25-26, 2016. The erroneous UTC offset information was broadcast by 15 GPS satellites, or half of the available constellation, during the anomaly. This paper discusses the technical reasons for the UTC offset anomaly, its effect on clocks controlled by GPS satellites (hereafter referred to as GPS clocks), and how it was detected at the National Institute of Standards and Technology (NIST). It then discusses the impact of the UTC offset anomaly on GPS clocks maintained and monitored by NIST, including clocks located in Boulder, Colorado and those at remote locations. Some analysis is presented of the effects of the UTC offset anomaly on GPS clocks located at 19 sites in North, Central, and South America.
1