DentistryImplant DentistryProsthodonticsImplant ProsthodonticsMaxillofacial ProsthodonticsMechanical Properties Of Dental MaterialsComputer-aided Design In ProsthodonticsOcclusal Scheme DesignOcclusal Scheme For Implant ProsthesesBiomechanics Of Dental ImplantsCortical Bone StructureFinite Element Analysis Of Stress ConcentrationFinite Element Stress AnalysisImplant Stress DistributionMaximum Intercuspation LoadOcclusal Load AnalysisStress
Abstract Purpose The aim of this study was to evaluate stress distributions on implants and alveolar bone due to occlusal load produced during chewing by prostheses prepared according to the All‐on‐Four concept with different occlusal schemes using a finite element analysis method. Materials and Methods On standard jaw models, teeth were set in accordance with the basic standards of canine‐guided occlusion, group function occlusion, bilateral balanced occlusion (BBO), lingualized occlusion, and monoplane occlusion schemes. Three‐dimensional (3D) images of these models were obtained using a surface scanner. Implants, superstructures, the maxilla, and mandible were modeled in the All‐on‐Four concept with 3D modeling software. Forces were defined on contacts formed in maximum intercuspation, lateral, and protrusive movement position for all 5 occlusion types. Stress outputs were recorded as maximum and minimum principal stresses (P max , P min ) and von Mises stress values for the implants. Results The highest P max value for the maxilla was observed in cortical bone in the group function occlusion during lateral movement (15.56 MPa). For the mandible, the highest P max value was observed on the cortical bone in maximum intercuspation of lingualized occlusion (72.75 MPa). The highest P min value for the maxilla was observed during the lateral movement in group function and for the mandible in BBO (–29.23 and –86.31 MPa, respectively). The lowest stress values were observed with canine‐guided occlusion in all related conditions and on all structures. Conclusions With the limitations of this simulation study, considering stresses on alveolar bone and implants in All‐on‐Four applications, the use of canine‐guided occlusion may be suggested.
38
Paulo Maló, Bo Rangert, Miguel de Araújo Nobre · Clinical Implant Dentistry and Related Research · 2003 · 763 citations
Tilting of posterior mandibular and maxillary implants for improved prosthesis support.
Leonard Krekmanov, M. Kahn, Bo Rangert et al. · PubMed · 2000 · 445 citations