International Journal of Dentistry · 2018 · 45 citations · 19 references
DentistryImplant DentistryProsthodonticsDigital Implant DentistryDigital ProsthodonticsImplant ImagingDigital Implant ProsthodonticsDigital Impression TechniquesImplant Position VerificationImplant Site AssessmentImplant-site ImagingIntraoral ScanningBiomedical ImplantsEdentulous Arch ScanningImplant Impression ScanningImplant Site AnalysisIntraoral Scan AccuracyScan Body AccuracyScanning AccuracyScanning Precision
Aim . To measure the trueness and precision under repeatable conditions for different intraoral scanners (IOSs) when scanning fully edentulous arch with multiple implants. Materials and Methods . Three IOSs and one industrial scanner were used to scan one edentulous master cast containing five implant scan bodies and three spheres. The cast was scanned thirty times with each scanner device. All scans were analyzed in the inspect software, and three-dimensional locations of the implants and the interarch distance between the spheres were measured. The values were compared to measurements made with one coordinate measuring machine (true value). One-way ANOVA was used to calculate the differences between IOSs and in comparison with the true value. Results . Significant differences were found between all IOSs. For the implant measurements, Trios 3 had the lowest trueness (≤114 μ m), followed by Trios 3 mono (≤63 μ m) and Itero element (≤−41 μ m). Trios had the lowest precision (≤135 μ m), followed by Itero element (≤101 μ m) and Trios 3 mono (≤100 μ m). With regard to the interarch distance measurements, Trios 3 had the lowest trueness (≤68 μ m), followed by Trios 3 mono (≤45 μ m) and Itero element (≤40 μ m). Trios 3 had the lowest precision (≤206 μ m), followed by Itero element (≤124 μ m) and Trios 3 mono (≤111 μ m). Conclusion . The results from this in vitro study suggest that precision is low for the tested IOS devices when scanning fully edentulous arches with multiple implants.
19
Tabea Flügge, Stefan Schlager, Katja Nelson et al. · American Journal of Orthodontics and Dentofacial Orthopedics · 2013 · 487 citations · Full text
The evolution of the CEREC system
Werner Mörmann · The Journal of the American Dental Association · 2006 · 389 citations · Full text
Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
Mario Imburgia, Silvia Logozzo, Uli Hauschild et al. · BMC Oral Health · 2017 · 389 citations · Full text
Frank S. Andriessen, David R Rijkens, Wicher J. van der Meer et al. · Journal of Prosthetic Dentistry · 2013 · 316 citations · Full text