IEEE Transactions on Industry Applications · 2018 · 70 citations · 21 references
EngineeringElectrical EngineeringEnergy SystemsRenewable Energy IntegrationRenewable Energy SystemsEnergy Management StrategiesEnergy Management SystemsEnergy StorageEnergy Storage IntegrationSolar Energy SystemsSolar Photovoltaic SystemsControl Of Energy Storage SystemsGrid-connected Photovoltaic SystemsIslanded OperationPower ConvertersPower Electronic ConvertersPower System IntegrationSolar Photovoltaic IntegrationSolar Photovoltaic Power Systems
Integrating storage with renewable PV and the grid improves reliability, efficiency, and reduces consumer electricity costs. The study proposes a power management strategy with automatic switching to optimize integrated PV‑ESU operation under time‑of‑use pricing. The PMS employs a 5‑kW PV array, a 3.5‑kWh lead‑acid battery ESU, and three converters to enable seamless switching between charging/discharging and grid modes, supply local loads during outages, and was validated in a laboratory FPGA‑based inverter setup. Experimental results demonstrate that the PMS is effective and robust across various scenarios.
In this paper, a power management strategy (PMS) for an integrated residential solar photovoltaic (PV) and energy storage unit (ESU) is proposed for both grid-connected and islanded operations to take the advantage of time-of-use pricing. This is an effective solution to integrate storage and renewable energy sources, such as solar PV, with the conventional grid to improve the reliability and efficiency of the power system and to reduce the total electricity cost for the consumer. An automatic switching control strategy is proposed to realize a smooth switching among the various operation modes of the proposed energy management strategy. The integrated PV-storage system is composed of a 5-kW PV array, a 3.5-kW·h ESU formed by 12-V single lead acid batteries, and three power converters. The PMS ensures seamless switching of the ESU converter between the charging and the discharging mode and seamless switching between the inverting and the rectifying mode of the grid converter. It also ensures that the local loads are supplied when the grid fails. An experimental setup has been implemented in the laboratory using the real-time field-programmable gate array general-purpose inverter control card from National Instrument to verify the practical feasibility of the proposed PMS under the various scenarios of the PV irradiation, load changings, and the state of charge of the ESU. The results show that the proposed PMS is effective and robust against various scenarios.
21
Haihua Zhou, Tanmoy Bhattacharya, Trần Như Dương et al. · IEEE Transactions on Power Electronics · 2010 · 695 citations