Oxford University Research Archive (ORA) (University of Oxford) · 2007 · 12 citations · 0 references
Open access
EngineeringMechanical EngineeringActuatorsOpticsProcess ControlAccelerator PhysicsControl SystemsElectron Beam PhysicsVibration ControlX-ray OpticsX-ray ProductionBeam InstrumentationBeam Position MonitoringElectron Beam GenerationHigh-resolution ImagingPositionProtein CrystallographySynchrotron X-ray Generation
Synchrotrons can produce very intense of X-rays and ultra violet light for a range of applications including protein crystallography, materials characterisation and high resolution imaging. The Diamond Light Source is a recently constructed synchrotron that produces a 3GeV electron beam in a ring of circumference 560m. A key component of the process is the fast beam stabilisation system that regulates the horizontal and vertical position of the beam in the presence of disturbances in the range 1 to 100Hz, using 178 sensors and actuators positioned around the ring. This report describes the design of controller dynamics for this system.