IEEE Transactions on Biomedical Engineering · 2018 · 73 citations · 39 references
Natural SciencesBiomedical EngineeringMaterials ScienceBiomedical ImagingCeramicsUltrasoundElectrical Properties Of CeramicsPiezoelectric CeramicsPiezoelectric MaterialsTransducer TechnologyUltrasonicsUltrasound ImagingLead-free Piezoelectric CeramicsLead-free PiezoelectricsPiezoelectric TransducersTransducer MaterialsTransducersUltrasonic ImagingUltrasonic TransducersUltrasound Imaging Transducers
High-frequency ultrasonic imaging with improved spatial resolution has gained increasing attention in the field of biomedical imaging. Sensitivity of transducers plays a pivotal role in determining ultrasonic image quality. Conventional ultrasonic transducers are mostly made from lead-based piezoelectric materials that may be harmful to the human body and the environment. In this study, a new (K,Na)NbO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> -KTiNbO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sub> -BaZrO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> -Fe <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> -MgO (KNN-NTK-FM) lead-free piezoelectric ceramic was utilized in developing eco-friendly transducers for high-frequency biomedical ultrasonic imaging applications. A needle transducer with a small active aperture size of 0.45 × 0.55 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> was designed and evaluated. The fabricated transducer exhibits great performance with a high center frequency (52.6 MHz), a good electromechanical coupling (k <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">eff</sub> ~ 0.45), a large bandwidth (64.4% at -6 dB), and a very low two-way insertion loss (10.1 dB). Such high sensitivity is superior to those transducers based on other lead-free piezoelectric materials and can even be comparable to the lead-based ones. Imaging performance of the KNN-NTK-FM needle transducer was analyzed by imaging a wire phantom and an agar tissue-mimicking phantom. Imaging capabilities of the transducer were further demonstrated by ex vivo imaging studies on a porcine eyeball and a rabbit aorta. The results suggest that the KNN-NTK-FM piezoceramic has many attractive properties over other lead-free piezoelectric materials in developing eco-friendly highly sensitive transducers for high-frequency biomedical ultrasonic imaging applications.
39
Yasuyoshi Saito, Hisaaki Takao, Toshihiko Tani et al. · Nature · 2004 · 5.5K citations
Superior Piezoelectric Properties in Potassium–Sodium Niobate Lead‐Free Ceramics
Jun Li, Xiang Lv, Jiagang Wu et al. · Advanced Materials · 2016 · 726 citations
Natural Sciences, Materials Engineering, Materials Science +17