DentistryDental Materials ScienceEndodonticsDental MaterialsMechanical Properties Of Dental MaterialsRoot Canal TherapyBioceramicsCalcium Phosphate BiomaterialsCalcium Phosphate MaterialsDental CeramicsEndodontic MaterialsSealant MaterialsBioactive Endodontic MaterialsBioceramic Sealing MaterialsCalcium Hydroxide MaterialsEndodontic BioceramicsGlass Ionomer CompositesRoot Canal Obturation MaterialsRoot Canal Sealing MaterialsX-ray Diffraction Analysis
Objective: This study aimed to evaluate setting reaction and the time of three bioceramics (Endosequence, iRoot-SP, and Smartpastebio) compared with glass ionomer (ActiV-GP) root canal sealers.Materials and methods: Setting reaction was tested using Fourier Transform Infrared Spectroscopy and X-ray Diffraction; setting time was measured using a Vicat needle.Results: Three-bioceramic sealers composed of calcium hydroxide, calcium phosphate, calcium silicate, silicon oxide, and zirconium oxide. During their setting, calcite and calcium phosphate silicate were detected. Their setting took longer time than ActiV-GP that have aluminum polyacrylate and calcium phosphate silicate in set mass.Conclusions: Bioceramic sealers took longer time to set than expected.
28
Physical Properties of 5 Root Canal Sealers
Huimin Zhou, Ya Shen, Markus Haapasalo · Journal of Endodontics · 2013 · 424 citations
Apatite‐forming ability (bioactivity) of ProRoot MTA
Maria Giovanna Gandolfi, Paola Taddei, Anna Tinti et al. · International Endodontic Journal · 2010 · 265 citations