Circulation Arrhythmia and Electrophysiology · 2018 · 65 citations · 17 references
MedicineCardiologySports MedicineClinical CardiologyPediatric CardiologySports CardiologyCardiac Risk AssessmentCardiogenic ShockElectrocardiographyImplantable Cardioverter-defibrillator CarePediatric Cardiac ElectrophysiologySports InjuriesCompetitive AthletesCongenital Long Qt SyndromeImplantable Cardioverter DefibrillatorsLong Qt Syndrome ElectrophysiologyMedical Records ReviewSerious Adverse EventsSports Injury EpidemiologySports Injury Risk
BACKGROUND: Despite safety concerns, many young patients with implantable cardioverter-defibrillators (ICDs) participate in sports. We undertook a prospective, multinational registry to determine the incidence of serious adverse events because of sports participation. The primary end points were death or resuscitated arrest during sports or injury during sports because of arrhythmia or shock. Secondary end points included system malfunction and incidence of ventricular arrhythmias requiring multiple shocks for termination. METHODS: Athletes with ICDs aged ≤21 years were included in this post hoc subanalysis of the ICD Sports Registry. Data on sports and clinical outcomes were obtained by phone interview and medical records review. ICD shocks and clinical details of lead malfunction were classified by 2 electrophysiologists. RESULTS: A total of 129 young athletes participating in competitive (n=117) or dangerous (n=12) sports were enrolled. The mean age was 16 years (range, 10-21; 40% female; 92% white). The most common diagnoses were long QT syndrome (n=49), hypertrophic cardiomyopathy (n=30), and congenital heart disease (n=16). The most common sports were basketball and soccer, including 79 varsity/junior varsity high school and college athletes. During a median follow-up of 42 months, 35 athletes (27%) received 38 shocks. There were no occurrences of death, arrest, or injury related to arrhythmia, during sports. There was 1 ventricular tachycardia/ventricular fibrillation storm during competition. Freedom from lead malfunction was 92.3% at 5 years and 79.6% at 10 years. CONCLUSIONS: Although shocks related to competition/practice are not uncommon, there were no serious adverse sequelae. Lead malfunction rates were similar to previously reported in unselected pediatric ICD populations. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00637754.
17
Charles I. Berul, George F. Van Hare, Naomi J. Kertesz et al. · Journal of the American College of Cardiology · 2008 · 396 citations
Medicine, Cardiology, Pediatrics +13