Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient‐reported outcomes
197
Citations
0
References
2018
Year
It is concluded that short implants (≤6 mm) are a valid option in situations of reduced bone height to avoid possible morbidity associated with augmentation procedures; however, they reveal a higher variability and lower predictability in survival rates. Narrow diameter implants with diameters of 2.5 mm and more demonstrated no difference in implant survival rates compared to standard diameter implants. In contrast, it is concluded that narrow diameter implants with diameters of less than 2.5 mm exhibited lower survival rates compared to standard diameter implants. It is further concluded that there are no differences between tapered versus non-tapered dental implants. Certain medications such as selective serotonin reuptake inhibitors and proton pump inhibitors showed an association with a higher implant failure rate.