Differences in Amino Acid Loss Between High-Efficiency Hemodialysis and Postdilution and Predilution Hemodiafiltration Using High Convection Volume Exchange—A New Metabolic Scenario? A Pilot Study

21

Citations

25

References

2018

Year

Abstract

The study shows that the AA losses in dialytic liquid are greater after high exchange volume HDF techniques, especially HDFpre. The AA losses are not metabolically compensated, so these increase the derangements of predialytic arterial plasma AA levels. Both AA losses and arterial AA perturbations further worsened body composition already after 12 months of additional dialysis.