Nanostructured TiO2 Carbon Paste Based Sensor for Determination of Methyldopa

Luane Ferreira Garcia, Carlos Eduardo Peixoto da Cunha, Emily Kussmaul Gonçalves Moreno, Douglas Vieira Thomaz, Rafael Luque, Vernon Somerset, Eric de Souza Gil

Pharmaceuticals · 2018 · 21 citations · 23 references

DOIFull text

Open access

Concepts

Abstract

Methyldopa is a catecholamine widely used in the treatment of mild to moderate hypertension whose determination in pharmaceutical formulae is of upmost importance for dose precision. Henceforth, a low-cost carbon paste electrode (CPE) consisting of graphite powder obtained from a crushed pencil stick was herein modified with nanostructured TiO₂ (TiO₂@CPE) aiming for the detection of methyldopa in pharmaceutical samples. The TiO₂-modified graphite powder was characterized by scanning electron microscopy and X-ray diffraction, which demonstrated the oxide nanostructured morphology. Results evidenced that sensitivity was nonetheless increased due to electro-catalytic effects promoted by metal modification, and linear response obtained by differential pulse voltammetry for the determination of methyldopa (pH = 5.0) was between 10⁻180 μmol/L (Limit of Detection = 1 μmol/L) with the TiO₂@CPE sensor. Furthermore, the constructed sensor was successfully applied in the detection of methyldopa in pharmaceutical formulations and excipients promoted no interference, that indicates that the sensor herein developed is a cheap, reliable, and useful strategy to detect methyldopa in pharmaceutical samples, and may also be applicable in determinations of similar compounds.

References