Radiation Protection Dosimetry · 2018 · 10 citations · 13 references
MedicineCardiologyRadiologyDiagnostic ImagingRadiation DosimetryRadiation SafetyCoronary AngiographyPatient-specific DosimetryQuality Assurance In DosimetryRadiation Dose MeasurementCumulative Radiation Dose AssessmentDicomDosimetry In Interventional ProceduresEye Lens DosimetryFluoroscopy Time AnalysisMedical Radiation Exposure MonitoringPatient Dose AssessmentPatient Dose Measurement
This study sought to assess patient and operator eye lens doses in diagnostic coronary angiography (DCA) and percutaneous coronary interventions (PCI) in a University hospital in Oman. Kerma area product (PkA), cumulative air kerma (CAK) and fluoroscopic time (FT) were retrospectively recorded from the DICOM header for 264 patients. The median (interquartile range) of FT, PKA and CAK were: 5.3 min (2.6-10.5), 60.9 Gy cm2 (41.3-91.4) and 0.86 Gy (0.61-1.29), respectively, for DCA procedures, and they were 20.2 min (13.3-30.1), 174.0 Gy cm2 (113.7-253.3) and 2.6 Gy (1.8-3.9), respectively, for PCI procedures. The results revealed wide variability in patient doses among individual patients. Monitoring and recording patient dose data can be valuable for quality assurance and patient safety purposes. Feedback to the operator may help optimize radiation doses to patients and prompt further action, as needed.
13
Preliminary reference levels in interventional cardiology
V. Neofotistou, E. Vañó, R. Padovani et al. · European Radiology · 2003 · 159 citations
Donald L. Miller, Stephen Balter, Robert G. Dixon et al. · Journal of Vascular and Interventional Radiology · 2011 · 109 citations · Full text
Guglielmo Bernardi, R. Padovani, Giorgio Morocutti et al. · Catheterization and Cardiovascular Interventions · 2000 · 95 citations
Medicine, Cardiology, Radiology +17