Late Presentation of an Iatrogenic Pseudoaneurysm of the Profunda Femoris Artery following Intramedullary Nailing
14
Citations
11
References
2018
Year
This case report illustrates the uncommon complication of pseudoaneurysm after intramedullary hip nailing. Because of the risk of potentially limb- and life-threatening complications, we advise careful drilling and placement of the distal locking screw. Excessive screw length should be avoided. The injured limb should be returned to the neutral position and lower-limb traction should be reduced before drilling the distal locking hole.