IEEE Journal of Solid-State Circuits · 2018 · 98 citations · 28 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsElectrophysiologySensorsBiomedical InstrumentationBiopotential MeasurementCardiac Action PotentialsMedical InstrumentationMicroelectrode ArraysMicroscale BiosensorsAction Potential GenerationDrug ScreeningElectrophysiological MeasurementElectrophysiological Signal AcquisitionIntracellular RecordingMultichannel Biopotential RecordingMultichannel Signal AcquisitionNoninvasive Sensing
Multi-electrode arrays (MEAs) are a candidate technology to screen cardiotoxicity <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">in vitro</i> because they enable noninvasive recording of cardiac beating rate, electrical field potential duration, and other parameters. In this paper, we present an active MEA chip featuring 16 384 electrodes, 1024 simultaneous readout channels, and 64 stimulation units (SUs) to enable six different cell-interfacing modalities: extracellular and intracellular recording, current and voltage stimulation, fast impedance motoring, and impedance spectroscopy (IS). The chip was designed and fabricated in a 0.13- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> Al CMOS technology, and the electrodes were fabricated on top of the silicon substrate using biocompatible TiN. Measurement results show a total input-referred noise of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$7.5 \pm 0.6~\mu \text{V}_{\mathrm{rms}}$ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$12.0 \pm 2.4~\mu \text{V}_{\mathrm {rms}}$ </tex-math></inline-formula> for the action potential and full bands, respectively, with a total power consumption of 95 mW for 1024 readout channels. We have experimentally validated the CMOS MEA in <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">in vitro</i> experiments, demonstrating all the different modalities. This novel platform will potentially enable high-throughput electrical activity monitoring and drug screening of cardiomyocytes.
28
Drug Discovery: A Historical Perspective
Jürgen Drews · Science · 2000 · 2.7K citations
Intracellular recording of action potentials by nanopillar electroporation
Chong Xie, Ziliang Lin, Lindsey Hanson et al. · Nature Nanotechnology · 2012 · 596 citations