Experimental calculations of number, energy and dose albedos for various materials using 662 keV gamma rays

Inderjeet Singh, Arvind D. Sabharwal, Bhajan Singh, B.S. Sandhu

Radiation effects and defects in solids · 2018 · 14 citations · 14 references

Concepts

Abstract

Number, energy and dose albedos are measured at a scattering angle of 180° for a broad beam of 662 keV gamma rays obtained from a radioactive source of 137Cs (having strength in µCi; 1 Ci = 3.7 × 1010 disintegrations per second). The gamma beam is incident on semi-infinite thick targets of variable atomic numbers. The scattering media is divided into three sets, which are pure elements, alloys and composite materials. Experiments are carried out using a 3″ × 3″ NaI(Tl) scintillation detector. To obtain precision in data, the response unfolding of a scintillation detector is used, which converts the observed pulse-height distribution to a true photon spectrum over the energy range of 2.5 to 640 keV. The detector response unfolding results in the true intensity of back-scattered gamma flux by shifting the events resulting from partial absorption of photons to the full energy peak of the spectrum. In the present study, albedo factors are studied as a function of target thickness and their atomic number. The experimentally calculated numbers of back-scattered gamma photon are in good agreement with theoretically generated numbers of multiple back-scattered counts by using a Monte Carlo simulation code. The experimental data on energy and intensity of 662 keV gamma photons are used to evaluate the number, energy and dose albedos for different materials under investigation.

References

14