Pediatric Anesthesia · 2018 · 10 citations · 12 references
Health ProfessionsRespiratory TherapyCritical Care TransportResuscitationVentilationAcute Respiratory Distress Syndrome VentilationCardiopulmonary ResuscitationMechanical VentilationMechanical Ventilation ModesPediatric Critical Care TransportTransport VentilationManometryPediatric Transport VentilationPrimary Outcome AnalysisTransport VentilatorsVentilation Strategies During ResuscitationVentilator Management During Transport
Abstract Background Positive‐pressure ventilation in critically ill patients is commonly administered via a manual resuscitation device or a mechanical ventilator during transport. Our group previously compared delivered ventilation parameters between a self‐inflating resuscitator and a flow‐inflating resuscitator during simulated in‐hospital pediatric transport. However, unequal group access to inline pressure manometry may have biased our results. In this study, we examined the performance of the self‐inflating resuscitator and the flow‐inflating resuscitator, both equipped with inline manometry, and several mechanical ventilators to deliver prescribed ventilation parameters during simulated pediatric transport. Methods Thirty anesthesia providers were randomized to initial resuscitator device used to hand ventilate a test lung. The resuscitators studied were a Jackson‐Rees circuit (flow‐inflating resuscitator) or a Laerdal pediatric silicone resuscitator (self‐inflating resuscitator), both employing manometers. The scenario was repeated using several mechanical transport ventilators (Hamilton‐T1, LTV ® 1000, and LTV ® 1200). The primary outcome was the proportion of total breaths delivered within the predefined target PIP / PEEP range (30 ± 3, 10 ± 3 cm H 2 O). Results The Hamilton‐T1 outperformed the other ventilators for breaths in the recommended range (χ 2 = 2284, df = 2, P < .001) and with no breaths in the unacceptable range (χ 2 = 2333, df = 2, P < .001). Hamilton‐T1 also outperformed all human providers in proportion of delivered acceptable and unacceptable breaths (χ 2 = 4540, df = 3, P < .001 and χ 2 = 639, df = 3, P < .001, respectively). Compared with the flow‐inflating resuscitator, the self‐inflating resuscitator was associated with greater odds of breaths falling outside the recommended range (Odds ratio (95% CI ): 1.81 (1.51‐2.17)) or unacceptable (Odds ratio (95% CI ): 1.63 (1.48‐1.81)). Conclusion This study demonstrates that a majority of breaths delivered by manual resuscitation device fall outside of target range regardless of provider experience or device type. The mechanical ventilator (Hamilton‐T1) outperforms the other positive‐pressure ventilation methods with respect to delivery of important ventilation parameters. In contrast, 100% of breaths delivered by the LTV 1200 were deemed unacceptable.
12
Comparison of methods of bag and mask ventilation for neonatal resuscitation
Neil N. Finer, Wade Rich, Alissa Craft et al. · Resuscitation · 2001 · 167 citations
Medicine, Child Health, Pediatrics +14