Plasma Science and Technology · 2018 · 16 citations · 28 references
Natural SciencesMaterials EngineeringMaterials ScienceElemental AnalysisMaterials CharacterizationMetallurgyAnalytical CalibrationCalibrationEquipment CalibrationOptical SpectroscopySpectroscopic Method ValidationTrace Element AnalysisCalibration CurvesLaser Energy AbsorptionLaser-based DiagnosticsLaser-induced BreakdownLaser-induced Breakdown SpectroscopyModel Calibration CurvesOptical BreakdownQuantitative Analysis Of Elements
In this paper, we developed a portable laser-induced breakdown spectroscopy (LIBS) using an optical fiber to deliver laser energy and used it to quantitatively analyze minor elements in steel. The R2 factors of calibration curves of elements Mn, Ti, V, and Cr in pig iron were 0.9965, 0.9983, 0.9963, and 0.991, respectively, and their root mean square errors of cross-validation were 0.0501, 0.0054, 0.0205, and 0.0245 wt%, respectively. Six test samples were used for the validation of the performance of the calibration curves established by the portable LIBS. The average relative errors of elements Mn, Ti, V, and Cr were 2.5%, 11.7%, 13.0%, and 5.6%, respectively. These results were comparable with most results reported in traditional LIBS in steel or other matrices. However, the portable LIBS is flexible, compact, and robust, providing a promising prospect in industrial application.
28
Laser Induced Breakdown Spectroscopy
Célio Pasquini, Juliana Cortez, Lucas M.C. Silva et al. · Journal of the Brazilian Chemical Society · 2007 · 1K citations · Full text
Laser-induced breakdown spectroscopy in China
Zhe Wang, Tingbi Yuan, Zongyu Hou et al. · Frontiers of Physics · 2013 · 218 citations