Is sonoelastography a helpful method of evaluation to diagnose Sjögren's syndrome?

Pía López‐Jornet, Berna Mestre Juan, Pina Frank, Aniorte Alegria Angela, José Gálvez, Berna Serna Juan de Dios

International Journal of Rheumatic Diseases · 2018 · 10 citations · 24 references

Concepts

Abstract

OBJECTIVE: A new sonoelastography technique - virtual touch tissue quantification of acoustic radiation force impulses (ARFI) - offers a promising method for measuring tissue rigidity. The aim of this study was to assess the usefulness of ARFI for diagnosing Sjögren's syndrome (SS). METHODS: This transversal prospective study included 41 patients with SS according to American-European Consensus Group (AECG) criteria, and a control group without symptoms. All subjects underwent ARFI high-resolution ultrasound assessment of the parotid glands (PG) and submandibular glands (SMG). RESULTS: In patients with SS, parotid gland shear wave velocity (SWV) was 2.08 m/s ± 0.55, significantly higher than in control subjects (1.2 m/s ± 0.17) (P = 0.0001); submandibular gland SWV was higher in SS patients (2.12 m/s ± 0.44) than control subjects (1.56 m/s ± 0.16) (P = 0.001). CONCLUSIONS: Acoustic radiation force impulses sonoelastography can assist diagnosis of SS, and is a non-invasive and fast method of detecting pathological changes to the parotid and submandibular glands.