European Journal of Trauma and Emergency Surgery · 2018 · 67 citations · 30 references
MedicineOrthopedic SurgerySurgeryCardiothoracic SurgeryPatient SafetyTrauma CareChest Trauma ManagementInternal FixationThoracic SurgeryThoracic TraumaTrauma ManagementTrauma SurgeryBlunt Thoracic InjuryBlunt Thoracic TraumaImplant RemovalIn-hospital MortalityLong-term Quality Of LifeMultiple FracturesRib FixationThoracic Trauma Surgery
PURPOSE: Rib fixation for flail chest has been shown to improve in-hospital outcome, but little is known about treatment for multiple rib fractures and long-term outcome is scarce. The aim of this study was to describe the safety, long-term quality of life, and implant-related irritation after rib fixation for flail chest and multiple rib fractures. METHODS: All adult patients with blunt thoracic trauma who underwent rib fixation for flail chest or multiple rib fractures between January 2010 and December 2016 in our level 1 trauma facility were retrospectively included. In-hospital characteristics and implant removal were obtained via medical records and long-term quality of life was assessed over the telephone. RESULTS: Of the 864 patients admitted with ≥ 3 rib fractures, 166 (19%) underwent rib fixation; 66 flail chest patients and 99 multiple rib fracture patients with an ISS of 24 (IQR 18-34) and 21 (IQR 16-29), respectively. Overall, the most common complication was pneumonia (n = 58, 35%). Six (9%) patients with a flail chest and three (3%) with multiple rib fractures died, only one because of injuries related to the thorax. On average at 3.9 years, follow-up was obtained from 103 patients (62%); 40 with flail chest and 63 with multiple rib fractures reported an EQ-5D index of 0.85 (IQR 0.62-1) and 0.79 (0.62-0.91), respectively. Forty-eight (48%) patients had implant-related irritation and nine (9%) had implant removal. CONCLUSIONS: We show that rib fixation is a safe procedure and that patients reported a relative good quality of life. Patients should be counseled that after rib fixation approximately half of the patients will experience implant-related irritation and about one in ten patients requires implant material removal.
30
Development and preliminary testing of the new five-level version of EQ-5D (EQ-5D-5L)
Michael Herdman, Claire Gudex, Andrew Lloyd et al. · Quality of Life Research · 2011 · 10K citations · Full text
Evaluation of Clinical Methods for Rating Dyspnea
Donald A. Mahler, Carolyn K. Wells · CHEST Journal · 1988 · 1.8K citations
Eileen M. Bulger, Matthew A. Arneson, Charles Mock et al. · The Journal of Trauma: Injury, Infection, and Critical Care · 2000 · 711 citations
Hideharu Tanaka, Tetsuo Yukioka, Yoshihiro Yamaguti et al. · The Journal of Trauma: Injury, Infection, and Critical Care · 2002 · 568 citations
Medicine, Clinical Sciences, Surgery +12