IFAC-PapersOnLine · 2018 · 18 citations · 9 references
EngineeringSystems EngineeringProcess ControlProcess DynamicsVibrationControl SystemsControl TheoryFeedback ControlProcess IdentificationSystem IdentificationTransfer FunctionsDynamic System IdentificationIdentification Of Dynamical SystemsParameter IdentificationSystem Identification For DynamicsSystem Identification In The Time DomainSystem Identification Under DisturbanceTransfer Function IdentificationTransport Parameter Estimation
This paper presents a method which can be used to identify dynamical systems using a biased relay feedback for control purposes. The method is applicable for systems describable by a transfer function if there are sustained oscillations in the biased-relay feedback test. It enables to estimate up to three frequency response points from a single biased relay test. These points can be used for fitting up to five parameters of a process transfer function with various structures. How to improve the parameter estimation of process models using a transport delay is shown as well. The proposed technique enables to improve the estimate of a static gain for a plant under a static load disturbance. The applicability of the method is demonstrated on simulated examples and on a laboratory apparatus called "Water Levitation". Matlab/Simulink programming environment was used for all experiments.
9