BMC Anesthesiology · 2018 · 15 citations · 23 references
MedicineChild HealthPediatricsLaryngologyPediatric OtolaryngologyPediatric PulmonologyAirway AssessmentAirway ManagementMechanical VentilationPediatric LaryngologyAirway Management In InfantsAirway Management In NewbornsCervical Collar UseDifficult Airway AssessmentIntubation Success RatesIntubation Training SimulatorsPediatric Airway AssessmentPediatric Difficult Airway Management
BACKGROUND: In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades with the time to ventilation via conventional direct laryngoscopy in a normal airway [NA] and in a simulated difficult airway [DA]. METHODS: This study was a comparative, bicentric, open-label, randomized controlled evaluation. An infant high-fidelity simulator (SimBaby™; Laerdal® Medical, Stavanger, Norway) was used, and two scenarios were proposed, as follows: NA and DA evoked with tongue edema and cervical collar. After theoretical and practical briefing, each participant compared in the two airway scenarios the novel King Vision™ Pediatric aBlade (KV) (Ambu® A/S, Bad Nauheim, Germany) video laryngoscope and the C-MAC™ D-blade Ped (DB) (Karl Storz® SE & Co. KG, Tuttlingen, Germany) video laryngoscope to conventional laryngoscopy using the Miller Blade (MiB) and the Macintosh Blade (MaB) in a random sequence. RESULTS: Eighty physicians (65 AN and 15 PCCM staff) were included. In the NA scenario, the median [IQR] time to successful time to ventilation (TTV) was significantly shorter for the KV at 13 s [12-15 s] than for the MaB at 14.5 s [13-16 s], DB at 14.5 s [13-16] and MiB at 16 s [14-19] (p < 0.001). In DA, the KV also shortened TTV to 14 s [13-16], whereas TTV was 23 s with the MaB [20-26], 19 s with the DB [16-21], and 27 s with the MiB [22-31] (p < 0.001). There were no differences in first-pass intubation success rates (FPAs) between hyperangulated blades and direct laryngoscopes in NA. In DA, the hyperangulated blades enabled 92 (DB) to 100% (KV) FPAs compared with 65 (MiB) to 76% (MaB) for conventional laryngoscopy (p < 0.001). CONCLUSION: Video laryngoscopes with hyperangulated blades were associated with shorter TTV in normal and difficult infant airway situations. The higher FPAs of hyperangulated blades in DA may avoid desaturations and decrease adverse events in pediatric airway management.
23
Difficult tracheal intubation in obstetrics
R. S. Cormack, J. R. Lehane · Anaesthesia · 1984 · 2.5K citations
Medicine, Anesthesiology, Obstetrics +10
John E. Fiadjoe, Akira Nishisaki, Narasimhan Jagannathan et al. · The Lancet Respiratory Medicine · 2015 · 443 citations
Benjamin T. Kerrey, Andrea S. Rinderknecht, Gary L. Geis et al. · Annals of Emergency Medicine · 2012 · 220 citations · Full text