Clinical ophthalmology · 2018 · 10 citations · 43 references
MedicineOphthalmologyVision ScienceAnterior SegmentOcular ImagingOphthalmic SurgeryContact Lens Clinical PracticeCorneal AnatomyCorneal DiseaseCorneal DisordersCorneal ImagingCorneal TopographyCentral Corneal Thickness MeasurementCorneal Thickness AssessmentCorneal Thickness ChangesCorneal Thickness DistributionKeratoconus Contact Lens ManagementKeratoconus ImagingPentacam ImagingPre-treatment
Aim: The aim of this study was to compare the pre- and posttreatment corneal densitometry and corneal thickness value of keratoconus (KCN) patients managed via contact lenses (CLs) or by both intrastromal corneal rings and contact lenses. Patients and methods: This prospective study was performed at the Manchester Royal Eye Hospital, UK. Patients were recruited before treatment and followed up for 12 months. Data of corneal densitometry and corneal thickness were collected using the Oculus Pentacam at the pretreatment visit and posttreatment visit at 12 months. Results: Corneal clarity significantly differs between both groups at pre treatment at zone 0–2 mm for the anterior layer ( P =0.002). The same diversity is present at zone 2–6 mm for the anterior layer ( P =0.003) and posterior layer ( P =0.008). The corneal clarity diversity found was not statistically significant at 12 months post treatment ( P >0.05). Corneal thickness was found to be statistically significantly different between pre treatment and post treatment for the CL group for central corneal thickness (CCT) and thinnest area ( P =0.01 and P =0.02), respectively. Discussion: This study shows that KCN management with Intacs was found to be effective in maintaining corneal clarity for a longer time than that with CL alone. On the other hand, corneal clarity reduces with disease progression in cases managed with CLs only. Analysis of Oculus Pentacam images provides an objective evaluation to monitor the corneal status after these different pathways of management. Keywords: keratoconus, contact lenses, densitometry, Intacs, keratocyte, haze
43
Corneal collagen crosslinking: a systematic review.
Nir Sorkin, David Varssano · PubMed · 2014 · 1.8K citations
Medicine, Ophthalmology, Surgery +17
Correcting keratoconus with intracorneal rings
Joseph Colin, Béatrice Cochener, Gwenaelle Savary et al. · Journal of Cataract & Refractive Surgery · 2000 · 542 citations
Medicine, Ophthalmology, Surgery +16
Inflammatory Molecules in the Tears of Patients with Keratoconus
Isabel Lema, José Antonio Durán · Ophthalmology · 2005 · 386 citations
Keratocyte Apoptosis After Corneal Collagen Cross-linking Using Riboflavin/UVA Treatment
Gregor Wollensak, Eberhard Spoerl, Michaela Wilsch et al. · Cornea · 2003 · 377 citations
Medicine, Dermatology, Ophthalmology +17