Review of Scientific Instruments · 2018 · 10 citations · 25 references
Natural SciencesNuclear EngineeringPhysicsDiagnostic ImagingPlasma PhysicsRadiation DetectionComputed TomographyComputed Tomography PhysicsHigh-temperature PlasmasMagnetized PlasmaPlasma DiagnosticsPlasma SimulationDiagnostic SimulationEmissivityMagnetohydrodynamic EffectsPhotodiodesSilicon PhotodiodesTomographic ImagingTomographic ReconstructionTomography
A diagnostic system for plasma radiated power tomography on Globus-M was upgraded with a new linear array based on silicon photodiodes. The hardware of the diagnostic system based on a 256-channel tangential matrix array and a 24-channel linear array is described. The algorithm for 2D tomographic reconstruction of plasma emissivity is presented. It uses the Tikhonov regularization method and anisotropic diffusion functional as a side constraint. Simulated plasma emissivity profiles were used to test and assess the capabilities of the developed algorithm. Data analysis was carried out in ohmic and neutral beam heated discharges to demonstrate the performance of the tomography diagnostic in plasmas with different parameters. The presented results illustrate the proper functioning of the tomography system that allowed to reveal and study various plasma phenomena, including magnetohydrodynamic mode.
25
Reconstruction of current profile parameters and plasma shapes in tokamaks
L. L. Lao, H. St. John, R.D. Stambaugh et al. · Nuclear Fusion · 1985 · 1.8K citations
X-ray tomography on the TCV tokamak
M. Antón, H. Weisen, M.J. Dutch et al. · Plasma Physics and Controlled Fusion · 1996 · 231 citations · Full text
R. Granetz, P. Smeulders · Nuclear Fusion · 1988 · 194 citations