Journal of the Chinese Medical Association · 2018 · 17 citations · 24 references
DentistryOrthodonticsAdult OrthodonticsDigital OrthodonticsOral DiagnosisComputer-aided Orthodontic DiagnosisDigital Model AnalysisOrthodontic ImagingCaliper CorrectionCaliper MeasurementClinical Test AccuracyIncisor Crowding AssessmentPaired T-testPaired Test Accuracy ComparisonPlaster CastsPlaster Model Digitization
BACKGROUND: This study aims to clarify whether 3Shape™ digital model system could be applied in orthodontic diagnostic analysis with certainty, especially under different crowding condition. Reliability, accuracy and efficiency of 3Shape™ digital model system were assessed by comparing them with traditional plaster cast. METHODS: 29 plaster casts with permanent dentition were transformed into digital models by 3Shape™ D800 scanner. All 29 models were categorized into mild-crowding (arch length discrepancy <3 mm), moderate-crowding (arch length discrepancy >3 mm and <8 mm), and severe-crowding group (arch length discrepancy >8 mm). Fourteen linear measurements were made manually using a digital caliper on plaster casts and virtually using the 3Shape™ Ortho Analyzer software by two examiners. Intra-class Correlation Coefficient (ICC) was used to evaluate intra-examiner reliability, inter-examiner reliability and reliability between two model systems. Paired t test was used to evaluate accuracy between two model systems. Kruskal-Wallis test followed by Mann-Whitney U test was used to evaluate the measurement differences between 3 groups in two model systems. RESULTS: Both intra-examiner and inter-examiner reliability were generally excellent for all measurements made on 3Shape™ digital model and plaster cast (ICC: 0.752-0.993). Reliability between different model systems was also excellent (ICC: 0.897-0.998). Half of the accuracy test showed statistically significant differences (p < 0.05) when digital models were compared with plaster casts. Furthermore, while assessing measurement differences between 3 groups in two model systems, the mandibular required space showed significant difference (p = 0.012) between mild crowding group (0.27 + 0.01 mm) and severe crowding group (0.20 + 0.09 mm). However, the differences were less than 0.5 mm and would not affect clinical decision. CONCLUSION: Using 3Shape™ digital model system instead of plaster casts for orthodontic diagnostic measurements is clinically acceptable.
24
Daron R. Stevens, Carlos Flores‐Mir, Brian Nebbe et al. · American Journal of Orthodontics and Dentofacial Orthopedics · 2006 · 329 citations
The accuracy and reliability of measurements made on computer-based digital models.
Meredith L Quimby, Katherine W. L. Vig, Robert Rashid et al. · PubMed · 2004 · 288 citations